Laminar Air Flow

Share: FacebookTwitterStumble
Laminar Airflow cabinets are designed for creation of a bacterial dust free air space. Laminar Airflow Cabinets are used for work with low-risk substances and materials, when protection of working material from environment is required or work with item requires a sterile working zone. Cabinets are used for equipment of local workplaces in medical, pharmaceutical and other institutes with high requirements for air cleanliness in the working zone.

Horizontal Laminar Air Flow
Horizontal Laminar Air Flow

We deal in manufacturing of horizontal laminar air flow that finds it applications in various hospitals, electronic industry and others. We use high grade component and quality raw material that is tested on various quality parameters and ensure smooth functionality.

Specifications:
  • Direction of flow: Horizontal
  • Cleanliness: CLASS 100
  • Velocity: 90 FPM + / -20%
  • Hepa Filter: Size and QTY. will depend on the Size selected
  • Particle retention: Above 0. 3 micron
  • Blower Assembly: 1 / 3 HP, 1440 RPM
  • Noise level: 65 decibel + / -5%
  • Rate of air flow: 0. 40 to 0. 75 M / Sec. (90 FPM)
  • Vibration level: < 2. 5 micron

Send Enquiry

Vertical Laminar Air Flow
Our vertical laminar air flow has vertical direction flow and particle retention above 0.5 micron. These are appreciated for their low noise and versatile usage. These have been designed with latest technology and can also be designed as per the specifications, provided by our clients. 

Application : The vertical laminar air flow cabinets is designed to provide a high degree of protection for process products In laboratories and production facilities. Many critical applications in the medical, pharmaceutical, nuclear-power, and micro electronic fields demand an ultra-clean work environment which is free from biological and particulate contamination. 

Operation : Ambient Air is draw in through pre-filter and is introduced in the work zone through the HEPA filter. The average velocity in the work zone is maintained between 0.4 and 0.5 m/s. Air cleanliness in the work zone is better than class 3.5 (100) in accordance with US FED STD 209 E

Construction : The cabinets are fabricated out of thick board duly sunmica clad or mild steel cabinet duly epoxy coated. The work table is made of thick board which is sunmica clad at top or S. S Table top will be provided as optional accessories. All joints are sealed with silastic sealant. Side panels are provided of thick transparent acrylic sheets. The unit is fitted with pre-filter and is made to pass through highly effective HEPA (High Efficiency Particular Air) filter having efficiency rating as high as 99.997% with hot, DOP, thus retaining all air-borne particles of size : 0.3 micron and larger. Using a dynamic machine, the blower and motor assembly is statically and dynamically balanced. Blowers are mounted on vibration isolation mounts to minimize vibration. The working is illuminated by fluorescent lightings fitted to the unit. Height of the working table provides comfortable “ Sit Down” working position for the operation to work on 220/230 volts AC. supply.

Air Velocity Between 0.4 to 0.5 mls +-20%
HEPA Efficiency Pre-filter   99.997% at 0.3 microns with DOP test Washable with an arrestance up to 90% at 5 microns Less than 65 dB (A)
Sound Level Lux 900 - 1300 Lux
Light Intensity Cleanliness Standard 209 E Class 100
Federal Power Supply 220 V Single phase 50 Hz
Optional : • S. S Table Top. • U. V Lights attachment • Front Acrylic Door • Gas/ Vacuum Cock • Castor wheels at the Bottom
VERTICAL LAMINAR FLOW HORIZONTAL LAMINAR FLOW
MODEL SIZE IN FT MODEL SIZE IN FT
VL-2A 2X2 HL-2A 2X2
VL-3B 3X2 HL-3B 3X2
VL-4C 4X2 HL-4C 4X2
Vertical Laminar Air Flow

Send Enquiry

Ceiling Laminar Airflow
Ceiling Laminar Airflow

Ceiling suspended laminar air flow (CLAF) are used for OT applications, pharma filling, operation theatre & packing line etc. CLAF provides ultra clean sterile HEPA filtered CLASS 100 air in a isolated area where the highly sensitive process activities are carried-out. Cleanair CLAF Laminar Air Flow available in complete stainless steel construction or GI construction with PU coated finish. Equipped with MINIPLEAT HEPA with dynamically balanced ultra-low noise blowers for optimum airflow. Differential pressure monitoring done through MAGNEHELIC gauges. Various sizes can be manufactured and supplied to suit the specific site conditions.

Send Enquiry

Industry We Cater to

  • Biotechnology
  • Tissue culture
  • Bio Chemistry
  • Botany
  • Zoology
  • Chemistry
  • Biology
  • Hospitals
  • Diagnostics Labs
  • Pharma Industry
  • Healthcare Industry
  • Vaccine manufacturers
  • Food Processing industry
  • Electronics service centre
  • Semiconductors
  • Space Applications
  • Life Science
  • Chemical Industry
  • Bio medical
  • Micro electronics
  • Micro biology
  • Clean room
  • Blood bank
  • College – zoology , botany , chemistry
  •  Medical implant
  • Medical devices
  • Educational institutions

  • Send Enquiry

    Product
    Showroom

    View all our products / services as a slide show.

    play now



    Contact Us

    Mr. Byju George (Managing Director) (Manager)
    Labtop House, Plot No. 59, Opposite Amarson, Near IPOL, Walive Phata, Sativali, Vasai East, District Thane
    Mumbai, Maharashtra - 401 208, India
    Telephone:  +(91)-(250)-6457376/ 6457377/ 6457378

    Contact via E-mail

    Contact via Mobile

    Contact via SMS

    Home  |  About Us  |  Products We Offer  |  Media Gallery   |  Site Map  |  Contact Us  |  Enquiry

    Member IndiaMART.com © Labtop Instruments, All Rights Reserved. (Terms of Use)
    Developed and Managed by IndiaMART InterMESH Limited